2012 December HLX-40/40A/40B Advanced Wireless Security Panel Hardware Installation and Programming Manual

Strany 2

Introduction 10 HLX-40 Installer Manual 1. Introduction 1.1 General The HLX-40 panel by Rosslare is the perfect wireless security system for intrus

Strany 3 - Table of Contents

Introduction HLX-40 Installer Manual 11 Figure 2: HLX-40A Figure 3: HLX-40B 1.2 Special Features  40 zones – 39 wireless zones, 1 wired zone – a

Strany 4

HLX-40 Quick Reference 12 HLX-40 Installer Manual 2. HLX-40 Quick Reference This chapter describes the control panel and the keypad, as well as the

Strany 5

HLX-40 Quick Reference HLX-40 Installer Manual 13 2.2 The Keypad Figure 5: HLX-40 Keypad Table 2 describes the keypad functions: Table 2: Keypad Fu

Strany 6

HLX-40 Quick Reference 14 HLX-40 Installer Manual Key Icon Press to Esc Ignore an entry or move one level up in a menu. 2.2.1 Keypad Operated Fun

Strany 7 - List of Figures

HLX-40 Quick Reference HLX-40 Installer Manual 15 Press To 9 Play User Message Listen to voice messages 2.3 Sound Indicators Table 4 presents the

Strany 8 - List of Tables

Specifications 16 HLX-40 Installer Manual 3. Specifications This chapter provides the various specifications in regard to all three HLX-40 control p

Strany 9 - Notice and Disclaimer

Specifications HLX-40 Installer Manual 17 3.2 Environmental Data Environmental Data HLX-40 HLX-40A HLX-40B Operation temperature: 0ºC to 60ºC (3

Strany 10 - 1. Introduction

Specifications 18 HLX-40 Installer Manual  Battery  Internal backup battery: 800 mAh for 6 hours standby- not EN50131-6 standard  Internal back

Strany 11 - Introduction

Installation HLX-40 Installer Manual 19 4. Installation 4.1 Unpacking the Equipment The contents of your package are listed below. First, make sure

Strany 12 - 2. HLX-40 Quick Reference

Copyright © 2012 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL, R

Strany 13 - HLX-40 Quick Reference

Installation 20 HLX-40 Installer Manual 4.4.1 Wiring the HLX-40 Figure 6: Panel Wiring Input Description Siren Relay output for external siren or

Strany 14

Installation HLX-40 Installer Manual 21 4.4.2 Resistors The HLX-40 family is provided with 2 10.0 kOhm resistors for the hardwire zone and Tamper co

Strany 15

Installation 22 HLX-40 Installer Manual Figure 8: Wiring to External Siren This output can be programmed by the installer to provide normally closed

Strany 16 - 3. Specifications

Installation HLX-40 Installer Manual 23 This wired input acts as a regular sensor and functions likewise in armed and disarmed mode. 4.4.6 Wiring th

Strany 17 - Specifications

Installation 24 HLX-40 Installer Manual To connect the MD-CC101 GSM stick: 1. Insert the GSM stick into the connector slots located on the back of t

Strany 18

Installation HLX-40 Installer Manual 25 4.8 Mounting the Back Plate 4.8.1 General To complete the installation without exposed wires, all the wirin

Strany 19 - 4. Installation

Installation 26 HLX-40 Installer Manual The optimum viewing angle of the LCD is achieved when the panel is mounted above the eyelevel of the user. Fi

Strany 20 - Installation

Installation HLX-40 Installer Manual 27 Figure 17: Backup Battery

Strany 21

Programming the HLX-40 28 HLX-40 Installer Manual 5. Programming the HLX-40 5.1 Overview We recommend that you program HLX-40 before installing it.

Strany 22 - Inside HLX-40

Installer Menu HLX-40 Installer Manual 29 6. Installer Menu The Installer’s menu enables access to the following group of options:  Change code 

Strany 23

Table of Contents HLX-40 Installer Manual iii Table of Contents 1. Introduction ...

Strany 24

Installer Menu 30 HLX-40 Installer Manual 6.2 Change Code CHANGE CODE Zones Enrolling Security Communications Automation Messages Maintenance Thi

Strany 25

Installer Menu HLX-40 Installer Manual 31 3. Once in the desired zone, use the Menu button to browse the options. 4. Press Enter to access the desi

Strany 26 - Eye level

Installer Menu 32 HLX-40 Installer Manual Browse the desired devices listed below to be enrolled using the Menu button and access it by pressing the

Strany 27

Installer Menu HLX-40 Installer Manual 33 6.4.2 Remote Controls You can enroll up to eight remote controls and specify functions for each button on

Strany 28 - 5. Programming the HLX-40

Installer Menu 34 HLX-40 Installer Manual 6.4.4 Keypads You can enroll up to four keypads. You can choose to remove enrolled keypads. To enroll/remo

Strany 29 - 6. Installer Menu

Installer Menu HLX-40 Installer Manual 35 6.5 Security The following is a list of the system’s security features. Change Code Zones Enrolling SECURI

Strany 30 - Installer Menu

Installer Menu 36 HLX-40 Installer Manual 6.5.1 Exit Delay An exit delay enables the user to arm the system and exit the site through a specified do

Strany 31

Installer Menu HLX-40 Installer Manual 37 6.5.4 Siren Time This specifies the amount of time the siren sounds when an alarm has been set off. The si

Strany 32

Installer Menu 38 HLX-40 Installer Manual 6.5.9 Supervision Time The supervision time submenu specifies the time limit during which the system recei

Strany 33

Installer Menu HLX-40 Installer Manual 39 6.5.12 Trouble Beeps This parameter determines whether the system emits a “trouble beep” indicated by a se

Strany 34

Table of Contents iv HLX-40 Installer Manual 4.6 Connect the AC Transformer ... 24 4.7 Con

Strany 35

Installer Menu 40 HLX-40 Installer Manual 6.5.15 Instant Arm Enables the user to instantly arm the system by bypassing the Exit Delay; Instant Arm i

Strany 36

Installer Menu HLX-40 Installer Manual 41 6.5.18 Alarm Cancel Specifies the amount of time during which if the user disarms the alarm, the system se

Strany 37

Installer Menu 42 HLX-40 Installer Manual 6.5.22 Key Beeps Choose to turn key beeps on to hear a beep on each key press; by default, Key Beeps is of

Strany 38

Installer Menu HLX-40 Installer Manual 43 To set the ready option: 1. Using the Menu button, select either Tamper, Low Battery, AC Fail, Comm Fail,

Strany 39

Installer Menu 44 HLX-40 Installer Manual 6.6 Communications Change Code Zones Enrolling Security COMMUNICATIONS Automation Messages Maintenance

Strany 40

Installer Menu HLX-40 Installer Manual 45 This menu allows you to define and setup the GPRS settings of the HLX-40 unit according to the network prov

Strany 41

Installer Menu 46 HLX-40 Installer Manual 2. Using the Menu button, choose the reporting options for each group as desired, the options are Disable,

Strany 42

Installer Menu HLX-40 Installer Manual 47 For PABX use the digit followed by "*" and then the full number. d. Account Code – The number t

Strany 43

Installer Menu 48 HLX-40 Installer Manual i. CS Primary – Using the Menu button, select either PSTN or GSM communication types. Press Enter to confir

Strany 44

Installer Menu HLX-40 Installer Manual 49 6.6.8 2-Way Voice Behavior The HLX-40 panel enables the CMS operator to open a 2-way voice session with th

Strany 45

Table of Contents HLX-40 Installer Manual v 6.5.13 Bypass Option ...

Strany 46

Installer Menu 50 HLX-40 Installer Manual 6.7 Automation Change Code Zones Enrolling Security Communications AUTOMATION Messages Maintenance

Strany 47

Installer Menu HLX-40 Installer Manual 51 Trigger PGM Activation Options Remarks Arm Away On, Off, Pulse, Ignore Arm Home On, Off, Pulse, Ignore

Strany 48

Installer Menu 52 HLX-40 Installer Manual 6.8.2 House Name This option enables you to type, record, and listen to the House Name as defined in the s

Strany 49

Installer Menu HLX-40 Installer Manual 53 6.9 Maintenance Change Code Zones Enrolling Security Communications Automation Messages MAINTENANCE

Strany 50

Installer Menu 54 HLX-40 Installer Manual 6.9.2 RF Test RF testing checks the signal strength of all the wireless devices enrolled to the system. If

Strany 51

Installer Menu HLX-40 Installer Manual 55 6.9.5 Test Devices This test checks the PGMs connected to the system. To test the PGM devices: 1. Select

Strany 52

User Menu Structure 56 HLX-40 Installer Manual 7. User Menu Structure The user menu enables basic user settings such as Time & Date update and u

Strany 53

Reading the Event Log HLX-40 Installer Manual 57 8. Reading the Event Log The HLX-40 event log stores up to 250 events. When the log is full, the ne

Strany 54

Sensor Placement and Helpful Reference Tables 58 HLX-40 Installer Manual A. Sensor Placement and Helpful Reference Tables A.1 Default Zone Descript

Strany 55

Sensor Placement and Helpful Reference Tables HLX-40 Installer Manual 59 A.2 Custom Zone Descriptions Custom Zone Description Custom #1 Custom #2

Strany 56 - 7. User Menu Structure

Table of Contents vi HLX-40 Installer Manual 6.9.5 Test Devices ...

Strany 57 - 8. Reading the Event Log

Sensor Placement and Helpful Reference Tables 60 HLX-40 Installer Manual Zone No. Zone Type Description Chime Yes/No No Activity Zone PGM 1 PGM 2

Strany 58 - 58 HLX-40 Installer Manual

Sensor Placement and Helpful Reference Tables HLX-40 Installer Manual 61 Zone No. Zone Type Description Chime Yes/No No Activity Zone PGM 1 PGM 2

Strany 59

Reporting Codes 62 HLX-40 Installer Manual B. Reporting Codes Table 8 provides a listing of the codes used to communicate with the CMS. Table 8: Lis

Strany 60

Reporting Codes HLX-40 Installer Manual 63 Programmable Feature Description CID Code Low system battery Restore (Panel Low Battery) R302 AC Loss Ev

Strany 61

Settings Requirements for CENELEC 64 HLX-40 Installer Manual C. Settings Requirements for CENELEC Quick Arm Enabled Jamming Enabled Tamper Enabled L

Strany 62 - B. Reporting Codes

Declaration of Conformity HLX-40 Installer Manual 65 D. Declaration of Conformity This equipment has been tested and found to comply with the limits

Strany 63 - Reporting Codes

Limited Warranty 66 HLX-40 Installer Manual E. Limited Warranty ROSSLARE ENTERPRISES LIMITED (ROSSLARE) TWO-YEAR LIMITED WARRANTY is applicable worl

Strany 64 - CENELEC

Limited Warranty HLX-40 Installer Manual 67 EXCLUSIONS AND LIMITATIONS ROSSLARE shall not be responsible or liable for any damage or loss resulting f

Strany 65 - Declaration of Conformity

HLX-40/40A/40B 0706-0960328+01 Asia Pacific, Middle East, Africa Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630 Fax: +8

Strany 66 - E. Limited Warranty

List of Figures HLX-40 Installer Manual vii List of Figures Figure 1: HLX-40 ...

Strany 67 - Limited Warranty

List of Tables viii HLX-40 Installer Manual List of Tables Table 1: Control Panel Functions .....

Strany 68 - 0706-0960328+01

Notice and Disclaimer HLX-40 Installer Manual ix Notice and Disclaimer This manual’s sole purpose is to assist installers and/or users in the safe an