Rosslare AC-215 Instalační příručka Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 39
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
AC-215 Single and Double Door Access Control Unit
Hardware Installation Guide
9
Door Alarm
This output is activated when either an alarm occurs in the system, or automatically by a time
zone. The following should be defined:
Single door controller:
Door 1 – OUT1A
Double door controller:
Door 1 – OUT1A
Door 2 – OUT2A
The output can be activated for a specified time and closes when the timer ends
Auxiliary
This output is activated when a transaction occurs in the readers that are either associated
with auxiliary, or automatically by a time zone. The following should be defined:
Single door controller:
Door 1 – OUT2
The output has two activations modes:
! Time – active for a specified time and closes when the timer ends.
! Toggle – active for every change in the output trigger. The trigger changes state.
General
This output is usually related to the general input or automatically by a time zone. The
following should be defined:
Single door controller:
Door 1 – OUT2A
The output has three activation modes:
! Follow input – output follows the input state
! Toggle – active for every change in the output trigger. The trigger changes state
!
Time – active for a specified time and closes when the timer ends
Zobrazit stránku 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 38 39

Komentáře k této Příručce

Žádné komentáře