Programming the AC-B/C/D3x
38 AC-B/C/D3x Family Installation and Programming Manual
If the Progr
amming Code is valid, all memory is erased, three
beeps are emitted, and the controller returns to Normal
mode.
If the Programming code is invalid, a long beep is emitted,
and the controller returns to Normal mode without erasing
the memory of the controller.
10.12 Replacing a Lost Programming Code
To be able to replace a lost programming code, the controller
must be in Normal mode. Before proceeding, verify that the
Mode LED is green.
1. Remove power from the unit.
2. Press the REX button.
3. Apply power to the unit while pressing the REX button.
4. Release the REX button.
5. You have 15 seconds to program a new Programming code into
the unit using the initial default code 1234 before the controller
reverts to the existing code.
10.13 Replacing a Lost Normal/Secure Code
To be able to replace lost Normal/Secure code, the
controller must be in Secure mode. Before proceeding,
verify that the Mode LED is red.
1. Remove power from the unit.
2. Press the REX button.
3. Apply power to the unit while pressing the REX button.
4. Release the REX button.
5. You have 15 seconds to program a new Normal/Secure code into
the unit using the initial default code 3838 before the controller
reverts to the existing code.