Rosslare AC-G43 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Numerické klávesnice Rosslare AC-G43. Rosslare AC-G43 Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - AC-F/G4x Family

AC-F/G4x Family Outdoor Backlit Standalone Controllers Installation and Programming Manual Models: AC-F43 AC-F44 AC-G43 AC-G44 AC-F4x AC-G4x

Strany 2

Introduction 10 AC-F/G4x Family Installation and Programming Manual  Selectable PIN code length up to 8 digits  Auxiliary input and auxiliary out

Strany 3 - Table of Contents

Introduction AC-F/G4x Family Installation and Programming Manual 11 1.4 Ancillary Equipment The following ancillary equipment may be required to co

Strany 4

Introduction 12 AC-F/G4x Family Installation and Programming Manual Figure 2: Front Panel of AC-G4x Series

Strany 5

Technical Specifications AC-F/G4x Family Installation and Programming Manual 13 2. Technical Specifications AC-F43 AC-F44 AC-G43 AC-G44 Input Vo

Strany 6 - List of Figures

Installation 14 AC-F/G4x Family Installation and Programming Manual 3. Installation Installation of an RFID reader adjacent to metallic surfaces mi

Strany 7 - List of Tables

Installation AC-F/G4x Family Installation and Programming Manual 15 6. Once wired, replace the controller back onto its back plate and secure using

Strany 8 - Notice and Disclaimer

Installation 16 AC-F/G4x Family Installation and Programming Manual Figure 4: Wiring Diagram for Lock Strike Relay & REX

Strany 9 - 1. Introduction

Installation AC-F/G4x Family Installation and Programming Manual 17 Figure 5: Wiring Diagram for Auxiliary Input & Output

Strany 10 - 1.3 Box Content

Installation 18 AC-F/G4x Family Installation and Programming Manual Figure 6: Wiring Diagram for the BL-D40 External Sounder

Strany 11 - 1.4 Ancillary Equipment

Operation AC-F/G4x Family Installation and Programming Manual 19 4. Operation • In the Operation chapter, “code” refers to a PIN code or proximity

Strany 12 - Introduction

Copyright © 2014 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to ROSSLARE ENTERPRI

Strany 13 - 2. Technical Specifications

Operation 20 AC-F/G4x Family Installation and Programming Manual In case of power failure, once the power is restored, the controller returns to Norm

Strany 14 - 3. Installation

Operation AC-F/G4x Family Installation and Programming Manual 21 4.3 Switching Operational Modes The three modes of operation defined above, can be

Strany 15 - 3.2 Wiring Instructions

Operation 22 AC-F/G4x Family Installation and Programming Manual auxiliary input is selected it de-activates the Norma/Secure mode code (see Section

Strany 16 - Installation

Operation AC-F/G4x Family Installation and Programming Manual 23 4.4.1 Auxiliary Input & Output For optimum usability in different applications,

Strany 17

Operation 24 AC-F/G4x Family Installation and Programming Manual 4.4.4 Lockout Feature (Keypad/Card Tamper) If the controller is presented with wron

Strany 18

Programming AC-F/G4x Family Installation and Programming Manual 25 5. Programming • In the Programming chapter, “code” refers to a PIN code or pro

Strany 19 - 4. Operation

Programming 26 AC-F/G4x Family Installation and Programming Manual Table 2 shows all the programming menus, with default factory codes and settings.

Strany 20 - 4.2 User Levels

Programming AC-F/G4x Family Installation and Programming Manual 27 5.1.1 Entering the Programming Mode • The controller must be in Normal mode to

Strany 21

Programming 28 AC-F/G4x Family Installation and Programming Manual 5.2 Changing the Open Code The open code is mainly used as a method to quickly te

Strany 22

Programming AC-F/G4x Family Installation and Programming Manual 29 5.3 Changing the Auxiliary Code The auxiliary code is mainly used as a method to

Strany 23 - 4.4.3 Tamper Feature

Table of Contents AC-F/G4x Family Installation and Programming Manual iii Table of Contents 1. Introduction ...

Strany 24 - 44BBL-D40 External Sounder

Programming 30 AC-F/G4x Family Installation and Programming Manual 5.4 Changing the Programming Code • The code 0000 is not valid; thus, the progr

Strany 25

Programming AC-F/G4x Family Installation and Programming Manual 31 You hear three beeps. The system returns to Normal mode. 5.6 Changing the Normal

Strany 26 - Programming

Programming 32 AC-F/G4x Family Installation and Programming Manual You hear three beeps. The system returns to Normal mode. 5.7 Setting Fail Safe/S

Strany 27 - To exit Programming mode:

Programming AC-F/G4x Family Installation and Programming Manual 33 You hear three beeps. The system returns to Normal mode. 5.8 Setting Auxiliary M

Strany 28 - 5.2 Changing the Open Code

Programming 34 AC-F/G4x Family Installation and Programming Manual Auxiliary Mode In addition to the Lock Strike relay and the Lock Strike REX, the c

Strany 29

Programming AC-F/G4x Family Installation and Programming Manual 35 Table 3: Quick Reference Guide for Auxiliary Mode Setting Auxiliary Mode Auxiliary

Strany 30

Programming 36 AC-F/G4x Family Installation and Programming Manual 5.8.2 Detailed Reference Guide The following subsections provide brief descriptio

Strany 31

Programming AC-F/G4x Family Installation and Programming Manual 37 be activated. The auxiliary input can switch the mode of operation of the controll

Strany 32

Programming 38 AC-F/G4x Family Installation and Programming Manual matches the condition of the magnetic contact switch; if the door opens, the auxil

Strany 33 - 5.8.1 General

Programming AC-F/G4x Family Installation and Programming Manual 39 5.8.2.9 Auxiliary Mode 8 Auxiliary input function: Green LED control Auxiliary ou

Strany 34

Table of Contents iv AC-F/G4x Family Installation and Programming Manual 4.4.3 Tamper Feature ...

Strany 35

Programming 40 AC-F/G4x Family Installation and Programming Manual 5.9 Setting the Lockout Feature If the controller is presented with wrong codes,

Strany 36

Programming AC-F/G4x Family Installation and Programming Manual 41 5.10 Backlight and LED Behavior This section is applicable for AC-Q4xHB/SB model

Strany 37

Programming 42 AC-F/G4x Family Installation and Programming Manual 5.11 Enrolling Codes 5.11.1 Primary Codes Definition  Primary codes can only b

Strany 38

Programming AC-F/G4x Family Installation and Programming Manual 43 5.11.4 Standard Method for Codes Enrolling To enroll codes using the Standard met

Strany 39

Programming 44 AC-F/G4x Family Installation and Programming Manual 5. Enter the code to be assigned as the primary or secondary code for this slot n

Strany 40

Programming AC-F/G4x Family Installation and Programming Manual 45 6. Enter the code to be used as the secondary code. If the secondary code is vali

Strany 41 - (backlight)

Programming 46 AC-F/G4x Family Installation and Programming Manual 4. Enter your programming code to confirm the deletion. If the programming code i

Strany 42 - 5.11 Enrolling Codes

Programming AC-F/G4x Family Installation and Programming Manual 47 strike and auxiliary relay. Assignment of such codes is achievable for any valid u

Strany 43

Programming 48 AC-F/G4x Family Installation and Programming Manual 5.13.2 Relay Code Assignment using Search Method To assign the relay code using S

Strany 44

Programming AC-F/G4x Family Installation and Programming Manual 49 5.14 Changing PIN Code Length/Factory Default Settings You must be very careful

Strany 45 - 5.12 Deleting Codes

Table of Contents AC-F/G4x Family Installation and Programming Manual v 5.13.1 Relay Code Assignment using Standard Method ...

Strany 46 - 5.13 Relay Codes Assignment

Programming 50 AC-F/G4x Family Installation and Programming Manual 5.15 Replacing a Programming Code The controller must be in Normal mode for the

Strany 47

Limited Warranty AC-F/G4x Family Installation and Programming Manual 51 A. Limited Warranty The full ROSSLARE Limited Warranty Statement is availab

Strany 48

AC-F/G4x Family Asia Pacific, Middle East, Africa Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 su

Strany 49 - Settings

List of Figures vi AC-F/G4x Family Installation and Programming Manual List of Figures Figure 1: Front Panel of AC-F4x Series ...

Strany 50

List of Tables AC-F/G4x Family Installation and Programming Manual vii List of Tables Table 1: Wiring Color Guide ...

Strany 51 - A. Limited Warranty

Notice and Disclaimer viii AC-F/G4x Family Installation and Programming Manual Notice and Disclaimer This manual’s sole purpose is to assist installe

Strany 52 - AC-F/G4x

Introduction AC-F/G4x Family Installation and Programming Manual 9 1. Introduction The AC-F4x series and AC-G4x series access control units are wate

Komentáře k této Příručce

Žádné komentáře